10.5 Instrument

The total station's various parameters that depend on its characteristics are configured by this option.

Instrument - TNL5 Instrument - TNL5 (2)

Reflector Type: Depending on the total station features, the program will show Prism, Reflector Sheet, Reflectorless and 360º Prism.

Laser Pointer: Allows one turn on/off the laser pointer of the total station.

Autolock: Allows one turn on/off the automatic search of the prism.

Instrument Precisions: Accuracy parameters of the total station, used within resection calculation, for calculating uncertainties of angles and distances.

Instrument - TNL5 (3)

R.Height (m): Allows one to change the reflector height (meters). This option is available only for Prism and Reflector Sheet.

Prism C. (mm): Allows one to change prism constant (milimeters)

Measurement Mode: Sets the accuracy for the measurements.

Setting Out Mov.: One can indicate if servo-assisted stations should be automatically rotated horizontally and/or vertically within setting out options.